Crosssection of HydroFlex
Reference electrode HydroFlex

Hydrogen Reference Electrode HydroFlex

Item number: 81010

HS code: 90303370

Country of origin: Germany

Our Standard Hydrogen Reference Electrode (RHE) HydroFlex can be used in almost any electrolyte.
Common sources of error such as diffusion potentials or contamination of the measuring electrolyte are eliminated. Therefore, HydroFlex is ideal for corrosion measurements.
Long-term measurements of up to 6 months are also possible without user intervention.

215,00 €

excl. Delivery

Delivery Time: approx. 1 - 5 Business Days
within Germany*

Overview

» Description                                                      » Technical Data                                 » Video: Commissioning of the Hydrogen Reference Electrode HydroFlex

» Comparison of our Reference Electrodes       » Recommended Accessories             » Further Information                         » You may also like                         » Still Questions?

Description Reference Electrodes

The platinum-hydrogen reference electrode is the reference electrode of first choice for standard-compliant measurement of potentials.

Platinum-hydrogen electrodes are the only reference electrodes that directly measure hydrogen ion activity

Our hydrogen reference electrode has a low resistance, so no shielded cables are necessary.

The reference electrode supplies itself with hydrogen gas from an internal source that can be easily replaced.

HydroFlex does not contain any internal electrolyte. This means there is no ion discharge and no diffusion potential. It requires low maintenance because no electrolyte needs to be refilled.

HydroFlex does not contain any toxic heavy metals.

Reference Electrodes HydroFlex and Mini-HydroFlex

Technical Data

Subject to technical changes.
 

Specifications
Description
Material

PTFE (Polytetrafluorethylene)
The edging of HydroFlex is made of PEEK (Polyetheretherketone).

Since HydroFlex is made of PTFE, it can be used in concentrated fluoride-containing electrolytes and in strongly acidic or strongly alkaline media (pH -2 to 16).

Shaft Diameter

8 mm

Shaft Length

80 mm

Diameter Head

25 mm

Sealings

EPDM (Ethylene-Propylene-Diene-Monomer-rubber)

Height Head

35 mm plus 6 mm for Hydrogen cartridge

Total Length

120 mm

Contact Socket

Gold-plated socket for 2 mm plugs

Sensor Element

Palladium-platin-gas diffusion electrode

Hydrogen Source

Replaceable hydrogen cartridge (88010)
Adjustable to 1 – 12 months
6 months recommended

Max. Temperature

210°C
as long as only the PTFE shaft is exposed to these temperatures

Crosssection of HydroFlex

Commissioning of the Hydrogen Reference Electrode HydroFlex

Comparison of our Reference Electrodes

Material: PTFE (Polytetrafluorethylene)
The edging of HydroFlex is made of PEEK (Polyetheretherketone).

Since HydroFlex is made of PTFE, it can be used in concentrated fluoride-containing electrolytes and in strongly acidic or strongly alkaline media (pH -2 to 16).

Max. Temperature: 210°C as long as only the PTFE shaft is exposed to these temperatures

For long-term measurements of up to 6 months

Shaft Diameter: 8 mm

Material Head: PTFE (Polytetrafluorethylene)
Material Shaft: PEEK (Polyetheretherketone)

The shaft length can be customized.
 

Max. Temperature: 80°C
 

For long-term measurements of up to 12 months

Shaft Diameter: 1.6 mm

 

For applications in confined spaces!

Recommended for use in our test cells FlexCell and ElyFlow!

Reference electrode Mini-HydroFlex with protection cap

Recommended Accessories

Hydrogen cartridge for HydroFlex

125 ml for operating time 1 – 12 months

The replacement cartridge can be stored without special requirements. However, it should be activated after about 2 years at the latest.

Discover our Products
Hydrogen Cartridge for HydroFlex

Test Lead 2/4 mm 0.5 mm2

Connector lead for HydroFlex and Mini-HydroFlex.

Please purchase this test lead when using Mini-HydroFlex in FlexCell or ElyFlow.

Discover our Products
Test Lead 2/4 mm for HydroFlex

Would you like to learn more about the hydrogen reference electrode HydroFlex?

How to Work with the Hydrogen Reference Electrode HydroFlex

Here you will find information on commissioning, maintenance and troubleshooting of the hydrogen reference electrode HydroFlex.

Learn more

Checking the Functionality of HydroFlex

Ideally, you should check the hydrogen electrode against a so-called master electrode, e.g. a calomel electrode, before your actual measurements. Here you will find more information about checking your HydroFlex or Mini-HydroFlex.

Learn more
Electrolytes in wich the hydrogen electrodes can be used.

Use of the Hydrogen Electrode HydroFlex

Here you will find out more about the electrolytes and solutions in which our hydrogen reference electrodes can be used. Also learn more about the use of HydroFlex as a Reversible Hydrogen Electrode, Normal Hydrogen Electrode, and Standard Hydrogen Electrode.

Learn more

You may also like

Hydrogen Reference Electrode HydroFlex Starterkit

Ideal starter kit for anyone who has not yet worked with the HydroFlex reference electrode.

259,00 €
Mini Hydrogen Reference Electrode Mini-HydroFlex

Gaskatel has further developed and reduced the size of the hydrogen reference electrode for use in confined spaces. The structure and functionality correspond to the hydrogen electrode HydroFlex – just smaller. Ideal for use in FlexCell and ElyFlow.

225,00 €
Digital Multimeter PeakTech 3430 USB

For the potential measurement with Hydrogen electrode HydroFlex, Mini-HydroFlex and the Hydrogen pH electrode pHydrunio. The digital multimeter has a USB interface for data transfer to a computer.

187,00 €

Still Questions?

Our FAQ section helps you to solve problems quickly and easily.
Browse through the following categories and find the right answer to your question.

If you have any further questions, please feel free to contact us.

You are also welcome to take a look at our guides and FAQ section.

Yes, according to IUPAC convention SO5917, the hydrogen reference electrode should be used.

The Mini-HydroFlex reference electrode is designed for our test cells FlexCell and ElyFlow. However, it offers additional advantages such as adjustable length and a relatively small diameter.

The HydroFlex, on the other hand, is more robust and, with a diameter of 8 mm, follows the recommendations for the outer dimensions of  reference electrodes.

Yes, both electrodes are electrodes of the first kind. You can place these electrodes directly into any kind of electrolyte.

Yes and no.
Measuring open-circuit potentials does not require a fixed position within the cell.
However, when applying some current to the electrochemical cell and thereby creating field line curvatures, you must use a Haber-Luggin capillary to adjust the correct position. Another advantage of the Haber-Luggin capillary is that it helps to protect the hydrogen electrode from parasitic oxygen gas bubbles.

Of course that is allowed. However, you will need to perform some calculations regarding the concentration and temperature effects on the AgCl potential. Furthermore, you will get liquid junctions potentials at the ceramic frit. These liquid junction potentials can be low in diluted electrolytes. However, at concentrations above 1 mol/L, they are no longer negligible.

Yes, the replacement cells can be stored. However, please mind the best before date.

The expiration date depends on the date of manufacture.
As a general rule, you should activate the cells after about 18 months at the latest. If in doubt, just ask us.
The reference electrode itself has no expiration date. You just need to remember to use a new hydrogen cell.

There are no special storage instructions to follow.

Yes, this is very important.
The replacement cells for HydroFlex are not compatible with Mini-HydroFlex, and vice versa.
Please be sure to purchase the hydrogen cells for Mini-HydroFlex and the hydrogen cartridges for HydroFlex.

The Mini-HydroFlex reference electrode is designed for our test cells FlexCell and ElyFlow. It also offers additional advantages such as adjustable length and a relatively small diameter.
However, please keep in mind that you will need an additional test lead.

You can also use our HydroFlex when using the test cells FlexCell. You will then need an additional connector available for FlexCell-PP or FlexCell-PTFE.
Please note that our HydroFlex is not compatible with the test cell ElyFlow! You have to use the Mini-HydroFlex instead.

Yes. Because of the exact position of the reference electrode and the usage of a Haber-Luggin capillary, you always measure the correct potential. The large distance  between the working electrode and counter electrode ensures that the entire working electrode has the same potential, regardless of the position on the surface.

Usually, you should place the reference electrode in front of the working electrode. However, you can also measure the voltage drop across the membrane or measure the potential at four different positions simultaneously.